What was found
THE 3 FASTENER HOLES OF THE SIDE BOX BEAM, UPPER FLANGE AT FRAME 43 LT, FOUND HOLE B & C CRACKED. CRACKS ARE AT 6 O'CLOCK POSITION AT BOTH HOLES, HOLE DIAMETER IS .248". REPAIR IAW ECRA 5331-01704.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE 3 FASTENER HOLES OF THE SIDE BOX BEAM, UPPER FLANGE AT FRAME 43 LT, FOUND HOLE B & C CRACKED. CRACKS ARE AT 6 O'CLOCK POSITION AT BOTH HOLES, HOLE DIAMETER IS .248". REPAIR IAW ECRA 5331-01704.