What was found
ON SHORT FINAL, LE DISAGREE, MISSED APPROACH. EICAS LE SLAT ASYM DISPLAYED. CREW REPORTED POSSIBLE WAKE TURBULENCE ENCOUNTER. PSEU BITE SHOWED LE OTBD ASYM MSG 27-81021. PROX BITE FAILED RT SLAT NR 8 INBD SENSOR 304. RAISED SLATS IN ALT MODE, MSG CLEARED. OPERATED FLAPS UP & DOWN SEVERAL TIMES, ALL OPERATIONS GOOD. CHECKED 304 SENSOR ADJUSTMENT IAW 27-88-01, ALL GOOD.