What was found
FOUND THE EPSU BATTERY AFT LT FAULTED, INOPERATIVE WHILE PERFORMING THE EMER LIGHTS OPERATIONAL TEST FROM THE NR 2 SVC. R & R THE EPSU 13WL AS REQUIRED IAW AMM 33-5 1-38. OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND THE EPSU BATTERY AFT LT FAULTED, INOPERATIVE WHILE PERFORMING THE EMER LIGHTS OPERATIONAL TEST FROM THE NR 2 SVC. R & R THE EPSU 13WL AS REQUIRED IAW AMM 33-5 1-38. OPERATIONS CHECKED GOOD.