As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN FLOORBEAM STATION 365 BETWEEN RBL 6 TO RBL 19, CORROSION. REMOVED CORROSION AT CABIN FLOORBEAM STATION 365, BL0 TO RBL 24.75 .027. REMOVED RBL 10.25 & .014, REMOVED AT RBL 14.25 FROM .125 THICKNESS FOR CLEANUP & IS OUT OF LIMITS. ALL OTHER BLEND AREAS OK IAW SRM 53-00-51. INSTALLED -1A REPAIR FOR OUT OF LIMITS, RBL 10.25 TO RBL 14.25 IAW ECRA 5310-05538.