What was found
FORWARD WET AREA, STATION 345 FLOORBEAM IS CORRODED FROM BL0 - 24L. REPAIRED FLOORBEAM UPPER CAP STATION 345 BETWEEN LBL 58 & RBL 60 IAW SRM 53-00-51 REPAIR 10 & ECRA 5310-06539.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD WET AREA, STATION 345 FLOORBEAM IS CORRODED FROM BL0 - 24L. REPAIRED FLOORBEAM UPPER CAP STATION 345 BETWEEN LBL 58 & RBL 60 IAW SRM 53-00-51 REPAIR 10 & ECRA 5310-06539.