What was found
DURING OXYGEN MASK MANUAL DROP TEST THE AFT LEFT FLIGHT ATTENDANT MASKS DROPPED & IT WAS NOTED THAT THE OXYGEN GENERATOR WAS MISSING. REPLACED OXYGEN MODULE LEFT AFT POSITION IAW AMM 35-21-10. TEST OF PASSENGER OXYGEN MASKS AMM 35-21-00. OPERATIONAL CHECKED GOOD.