As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INFLIGHT LT HYD QTY LIGHT ILLUMINATED, FOLLOWED BY RESERVOIR LIGHT. HYD QTY READ ZERO, ENG HYD PUMP TURNED OFF WITHIN 3 MINUTES. ELEC HYD PUMP TURNED OFF WITHIN 5 MIN. R & R DAMAGED LT MLG DOWNLOCK RETURN LINE IAW CHAPTER 20. SERVICED THE LT HYD SYS RESERVOIR. PERFORMED MAIN HYD SYS INSPECTION IAW AMM 29-11-00. NO DEFECTS NOTED.