What was found
SPEED 220, FLAPS 5 SELECTED, TE FLAPS SPLIT 1 NEEDLE WIDTH BOTH BETWEEN FLAPS, FLAPS 0 INDICATOR SPEED UP TO 230 KTS, FLAP NEEDLES BECAME SYMMETRICAL REF BITE PROCEDURE. FOUND FAULT IAW FIM TASK 27-51 TASK 848. REPLACED RT FLAP POSITION TRANSMITTER IAW AMM 27-58-01-400-801. REF BITE CHECK PASSED, LAND VERIFY.