What was found
AFT PIT BILGE, SHEAR TIE ANGLE AT STATION 1600, BETWEEN STRINGER 29 - 28L HAS CORROSION. REMOVED & INSTALLED NEW SHEAR TIE IAW DWG 146N1021-224 & SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT BILGE, SHEAR TIE ANGLE AT STATION 1600, BETWEEN STRINGER 29 - 28L HAS CORROSION. REMOVED & INSTALLED NEW SHEAR TIE IAW DWG 146N1021-224 & SRM 51-40-02.