What was found
FUEL CONFIRMED LEAKING AFTER TAKEOFF. CHECKLIST PROCEDURE & ENG SHUTDOWN PERFORMED. R & R HPTACC ON NR 1 ENG IAW MM TASK 75-21-01-000-801-F00, 75-21-01-400-801-F00, REF NR 4913120 PP TEST 3A 12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUEL CONFIRMED LEAKING AFTER TAKEOFF. CHECKLIST PROCEDURE & ENG SHUTDOWN PERFORMED. R & R HPTACC ON NR 1 ENG IAW MM TASK 75-21-01-000-801-F00, 75-21-01-400-801-F00, REF NR 4913120 PP TEST 3A 12.