What was found
HFEC INSPECTION DETECTED A CRACK INDICATION AT STATION 727B, RBL45.50, TWO HOLES EACH, AFT INBD & AFT OTBD. ACCOMPLISHED STRAP REPAIRS IAW RES-WI 2009633-4 & ECRA 5320-02627.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HFEC INSPECTION DETECTED A CRACK INDICATION AT STATION 727B, RBL45.50, TWO HOLES EACH, AFT INBD & AFT OTBD. ACCOMPLISHED STRAP REPAIRS IAW RES-WI 2009633-4 & ECRA 5320-02627.