What was found
IN COMPLIANCE WITH AD 2013-23-04, THREE EACH CRACKS NOTED AT STATION 727B, RBL 24.75 ONE EACH INBD FLANGE, OTBD FLANGE. REAMED DAMAGE HOLES, TRIMMED AREAS, FABRICATED REPAIR SPLICES, FILLERS, TREATED, PRIMED & INSTALLED IAW ECRA 5320-02635 & RES 2009474-3.