What was found
AFT CABIN FLOOR STRUCTURE & AREA BELOW THE FLOOR LT STATION 1681, BETWEEN LBL 0 & LBL 60, SUBFLOOR SHOWS EVIDENCE OF SURFACE CORROSION. REMOVED CORROSION ON DECK PLATE, STATION 1681, LBL 12, LBL 24, LBL 40 X LBL 48, MAT LOST LBL 12 .031, LBL24, .016,LBL 40 .018 & AREAS BEYOND LIMITS LBL 48, .005 WITHIN LIMITS IAW SRM 53-60-51 FIG 101. FABRICATED REPAIR DOUBLER IAW SRM 53-60-51 REP 2. TREATED, PRIMED & TOP COATED AREAS IAW AMM 51-21-04.