What was found
DENT AT STATION 270, 1" BELOW STRINGER -18R, RIVET LINE IS OUT OF LIMITS IAW SRM 53-00-01. ALLOWABLE DAMAGE 1 PAR 3 B 3 DETAIL G. CHEM-MILL STEP IS WITHIN DENT RESIDUAL PERIMETER. REPAIRED DENT IAW SRM 53-00-01 REPAIR 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT AT STATION 270, 1" BELOW STRINGER -18R, RIVET LINE IS OUT OF LIMITS IAW SRM 53-00-01. ALLOWABLE DAMAGE 1 PAR 3 B 3 DETAIL G. CHEM-MILL STEP IS WITHIN DENT RESIDUAL PERIMETER. REPAIRED DENT IAW SRM 53-00-01 REPAIR 3.