What was found
STRINGER 35R, FRAME 65 - 66 HAS OUT OF ROUND HOLES. REMOVED DAMAGED STRINGER 35R FROM FRAME 65 - 66. FABRICATED REPLACEMENT STRINGER. LOCATED, DRILLED & DEBURRED, INSTALLED & REST ORD SURFACE PRO IAW SRM 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 35R, FRAME 65 - 66 HAS OUT OF ROUND HOLES. REMOVED DAMAGED STRINGER 35R FROM FRAME 65 - 66. FABRICATED REPLACEMENT STRINGER. LOCATED, DRILLED & DEBURRED, INSTALLED & REST ORD SURFACE PRO IAW SRM 51-75-12.