What was found
REFERENCE DAMAGE 4917583. DENT AT STATION 500E IN BETWEEN STRINGER 26R & 27R, W=1.3, Y=.052, W/Y=25, DENT IS OUT OF LIMITS IAW SRM 53-00-01 FIG 103 DET G. REPAIRED DENT, INSTALLED REPAIR DOUBLER AT STATION 500E, BETWEEN STRINGER EXTERNAL DETAILED VISUAL AT ARROW 5 LOCATION. EVERY 7,000 FLIGHT IAW SRM 55-00-01 REPAIR 3 PAGE 208 TABLE 205. STRINGER 26R & 27R SEE ALL SUB TASKS & WIPS FOR WORK. ISSUED DIP TO READ INTIA ON, EVERY 36,000 FLIGHT CYCLES PERFORM A INTERNAL HFEC INSPECTION, INSPECTION THRESHOLD 50,000 FLIGHT CYCLES, REPEAT INTERVAL, ARROW 9 LOCATION, & AN INTERNAL DETAILED VISUAL AT ARROW 7. INSPECTIONS THEREAFTER EVERY 4,000 FLIGHT CYCLES PERFORM A LOCATION & AN EXTERNAL LFEC INSPECTION BEFORE 50,000 TOTAL CYCLES, PERFORM THE INSPECTIONS AS NOTED IN SRM 53-00-01 REPAIR 3 TABLE 205.