What was found
VERTICAL STAB AUX SPAR, FRONT SPAR CROWN SKIN PANEL 2108 - 2195, LT SIDE FOUND AREAS OF CHAFING. INTERIM REPAIR DOUBLER INSTALLED STATION 2108-2184, STRINGER 1 - 3L IAW ECRA 5330-05503 REV 0 PART 1 3. REQUIRES DIP TO ACCOMPLISH INSPECTIONS IN PART 2 OF THE ECRA. PLANNING ON TOMC TO CONTACT UAL EG AFTER REACHING 28000 CYCLES BUT BEFORE 29000 CYCLES FOR INSPECTION REQUIREMENTS. CREATE DIP IAW ECRA 5330-05503 TOMC APPROVED.