What was found
AFT PASS CABIN, STATION 1640, LBL 9" - RBL 4", FLOORBEAM SCREW HOLES, 3 EA HAVE CORROSION. CORROSION OUT OF LIMITS, ACCOMPLISHED REPAIR IAW SRM 51-10-02, 53-00-51, 51-20-01 & 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PASS CABIN, STATION 1640, LBL 9" - RBL 4", FLOORBEAM SCREW HOLES, 3 EA HAVE CORROSION. CORROSION OUT OF LIMITS, ACCOMPLISHED REPAIR IAW SRM 51-10-02, 53-00-51, 51-20-01 & 53-00-51.