FLOORBEAM AT STATION 986.5 HAS CORROSION & ONE BAD 1/4" DOME NUTPLATE AT RBL 43. ACCOMPLISHED PERMANENT REPAIR IAW SRM 53-00-51 REPAIR 1. REPLACED DOME NUTPLATE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT STATION 986.5 HAS CORROSION & ONE BAD 1/4" DOME NUTPLATE AT RBL 43. ACCOMPLISHED PERMANENT REPAIR IAW SRM 53-00-51 REPAIR 1. REPLACED DOME NUTPLATE IAW SRM 51-40-02.