What was found
MAIN CABIN FLOOR SUPPORT WEB, UPPER ATTACH ANGLE HAS A CRACK AROUND FASTENER HOLE, BS 752, LBL 49.5. R & R IAW SRM 51-40-02 & DWG 140T2540.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR SUPPORT WEB, UPPER ATTACH ANGLE HAS A CRACK AROUND FASTENER HOLE, BS 752, LBL 49.5. R & R IAW SRM 51-40-02 & DWG 140T2540.