What was found
CIRCUIT BREAKER STBY BUS SECT 1 POPPED, SLIGHT SMOKE & ODOR LOST DU 1 - 3 EEC`S BOTH WENT TO AL, YAW DAMPER INFO, NR 1 COMM & NAV RADIOS INOPERATIVE. REVERSER NR 1 DID NOT DEPLOY ON LANDING. R & R SPCU IAW AMM 24-34-11-400-801. PERFORMED OPERATIONS CHECK ON SYS INVOLVED, ALSO DFCS BITE & LAND VERIFY NO FAULTS FOUND. RAN BOTH ENGS, PACKS ON, NO ODOR NOTED. INSPECTED CTR & UPPER DU`S, ALL OK. ALSO AMM 05-51-26 BLOCK 210 WITH THE EXCEPTION OF C & D AS APPROVED.