As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT NR 5 MAIN ENTRY DOOR AFT UPPER CUT OUT SKIN CRACK, STATION 2280, 3" DOWN FROM STRINGER 16R, LENGTH=1". REPAIRED IAW EN -53-0322. REPAIR ACCOMPLISHED IAW EVA 80571 ECRA 5300-05671 REV. REMOVED RIVETS AS SHOWING IN FIGURE 1, PERFORMED OPEN HOLE HFEC INSPECTION OF THIS RIVETS HOLE & NO CRACKS OR OTHER DEFECTS WERE FOUND. INSTALLED NEW RIVETS AT THE AREA.