What was found
DENT BETWEEN BS 1016 & 1040 IS ON STRINGER 15L & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01 PG 105, STP 3 B I. REMOVED DAMAGE, FABRICATED & INSTALLED REPAIR DOUBLER & FILLERS IAW SRM 53-80-01 REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT BETWEEN BS 1016 & 1040 IS ON STRINGER 15L & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01 PG 105, STP 3 B I. REMOVED DAMAGE, FABRICATED & INSTALLED REPAIR DOUBLER & FILLERS IAW SRM 53-80-01 REPAIR 2.