What was found
RIGHT STA 1120, R70 TENSION TIE AREA FOUND 1 EA FASTENER HOLE CRACKED AT FWD CHANNEL LAYER APPROXIMATELY 1-8" IN LENGTH AT 1 O`CLOCK POSTION. BS 1120, FWD AND AFT TENSION TIE CRACKED AREA REPAIRED IAW SRM 53-40-30, FIG 201, REPAIR 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT STA 1120, R70 TENSION TIE AREA FOUND 1 EA FASTENER HOLE CRACKED AT FWD CHANNEL LAYER APPROXIMATELY 1-8" IN LENGTH AT 1 O`CLOCK POSTION. BS 1120, FWD AND AFT TENSION TIE CRACKED AREA REPAIRED IAW SRM 53-40-30, FIG 201, REPAIR 1.