What was found
FRAME DENTED BS 1480, STR 25-26L CUTOUT DAMAGED AREA BETWEEN STR 25-26L, FUSELAGE LOWER LOBE FRAME REPAIR AT STA 1480 BETWEEN STR 23- 26L REF SRM 53-00-07, FIG 201, REP 5, CAT B REPAIR. INSP THRESHOLD 37500, F/C AFT REPAIR AND REPEAT AT 12 000 F/C INTERVALS.