What was found
RIGHT ELEVATOR UPPER SKIN PANEL HAS A PUNCTURE, 28 INCHES FROM INBD, .75 INCHES FROM TE. DAMAGE REMOVED AND INSTALLED WET LAYUP REPAIR IAW SRM55-21-11, PAR 5D. SRI 55-21-11, TABLE 203.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT ELEVATOR UPPER SKIN PANEL HAS A PUNCTURE, 28 INCHES FROM INBD, .75 INCHES FROM TE. DAMAGE REMOVED AND INSTALLED WET LAYUP REPAIR IAW SRM55-21-11, PAR 5D. SRI 55-21-11, TABLE 203.