What was found
FRAME 67 HAS OUT OF ROUND HOLES AT STRINGERS 23 - 32R. INSTALLED A NEW FRAME AND SPLICE IAW SRM 51-72-11, & 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 67 HAS OUT OF ROUND HOLES AT STRINGERS 23 - 32R. INSTALLED A NEW FRAME AND SPLICE IAW SRM 51-72-11, & 51-42-11.