What was found
NR 2 ENG HYD PUMP LOW PRESSURE LIGHT ILLUMINATED. PUMP TURNED OFF IAW CKLST. SYS B QTY WENT TO ZERO. HYD PUMP SHAFT FOUND SHEARED, REPLACED THE HYD PUMP SHAFT, ASSOCIATED FILTERS, SYSTEM FLUSHED, RUNS AND LEAK CHECKED GOOD
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENG HYD PUMP LOW PRESSURE LIGHT ILLUMINATED. PUMP TURNED OFF IAW CKLST. SYS B QTY WENT TO ZERO. HYD PUMP SHAFT FOUND SHEARED, REPLACED THE HYD PUMP SHAFT, ASSOCIATED FILTERS, SYSTEM FLUSHED, RUNS AND LEAK CHECKED GOOD