What was found
AFTER RT ENGINE GENERATOR DRIVE DISCONNECTED, APU NO START ON FIRST ATTEMPT, 2ND ATTEMPT STARTED AND RAN FOR ONE MINUTE THEN AUTO SHUTDOWN WITH EICAS MESASGE APU OIL QTY, T/865-15. DIVERTED MAINTENANCE CHECKD APU OIL IAW MM 12-13-04(301). FOUND APU OIL LEVEL BELOW THE APU FULL MARK ON SIGHT GAGE AND EVIDENCE OF OIL WETNESS IN APU COMPARTMENT. SERVICED APU TO FULL, R & R APU CONTROLLER IAW AMM 49-62-00, OPS CHECKED GOOD. INSTALLED NEW GEN PHASE LEADS AMM 24-21-07