What was found
LEFT HORIZONTAL STAB LOWER SKIN AT STA.110 HAS THREE CRACKS MARKED AT 29"1/2"LONG,20"1/2"LONG,AND 11"1"LONG, ALL FROM AFT SPAR. INSTALLED DOUBLER AND FILLER ISSUED DIP TO INSPECTION THRESHOLD 56,000 FLT CYCLES AND REPEATED INSPECTION ON EVERY 9,000 FLT CYCLES IAW SRM 55-10-01 REPAIR 11 PAGE 218.