What was found
CABIN FLOORBEAM TED CAP CORROSION AT BS 947, LBL 50. REMOVED AND REPLACED THE TEE IAW SRM. 53-70-51, REPAIR 5, ALTERNATIVE 2
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM TED CAP CORROSION AT BS 947, LBL 50. REMOVED AND REPLACED THE TEE IAW SRM. 53-70-51, REPAIR 5, ALTERNATIVE 2