What was found
DURING INITIAL CLIMB STRONG VIBRATION, NR 1 ENGINE STRONG VIBRATION NR 1 ENG SURGED/TORCHED STRONG BURNING SMELL. LANDED OVERWEIGHT 165,000 ACCOMPLISHED NR 1 ENG BORESCOPE PER AMM 72-00-00-200-804-FOO, NO LIMITING DEFECTS FOUND. ACP'D OVERWEIGHT LANDING INSPECTION REF AMM 05-51-35-210-801, 05-51-35-201.