What was found
FRAME 68 ABOVE STR 23R CORRODED. CUT OUT DAMAGED AREA AND FABRICATED A REPAIR FITTING IAW SRM 53-41-12 FIG 202 AND INSTALLED IAW SRM 53-41-12 FIG 202 PARA 5-B AND SRI 53-41-12-1-002-00 PARA 5.B 202
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 68 ABOVE STR 23R CORRODED. CUT OUT DAMAGED AREA AND FABRICATED A REPAIR FITTING IAW SRM 53-41-12 FIG 202 AND INSTALLED IAW SRM 53-41-12 FIG 202 PARA 5-B AND SRI 53-41-12-1-002-00 PARA 5.B 202