What was found
TE FLAP DISAGREE EICAS MESSAGE DURING CONFIGURATION FOR LANDING, FLAPS 5. T/E ASSY DISAGREE CHECK LIST ACCOMPLISHED, NORMAL LANDING. FSEU BITE,FIM 27-51 FT 809 SHOWS NO EXISTING FAULTS, LAST FLT LEG SHOWS MAINT MESSAGE 27-51104. TROUBLESHOT IAW FIM 27-51 FT 810. FLAPS MOVED TO POS 30 POS WITHOUT FAULT. INSPECTED THE TE FLAP ROTARY ACTUATORS , FOUND OVERLOAD TRIP INDICATOR ON ACTUATORS 2,3 AND 7 TRIPPED. IAW FIM, TRIP INDICATORS RESET, EXTENDED AND RETRACTED FLAPS WITH PRIMARY POWER IAW AMM 27-51-00-0201 TWO TIMES WITHOUT FAULTS. ALTERNATE FLAP POWER CIRCUIT BREAKER ON P6-4 GRID D24 TRIPPED. REPLACED ALTERNATE TE MOTOR ASSY CIRCUIT BREAKER IAW AMM 27-51-34 PB 201. OPS CHECKED OK.