As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AROUND FASTENER HOLES ON THE AFT CARGO COMPARTMENT FLOOR SUPPORT STRUCTURE RT SIDE PANEL BETWEEN BS 1380 TO BS 1440 CARGO DOOR LOWER CUTOUT AREA. REMOVED AND REPLACED FLOOR SUPPORT STRUCTURE RT PANEL IN AFT CARGO BS 1380 TO BS 1440 CARGO DOOR LOWER CUTOUT AREA IAW SRM 51-40-02 PAR 7 FIG 12.