What was found
FUSELAGE DENTED IN AREA FORWARD OF EXISTING REPAIR AT STATION 620 STR 16L REF NR 9006912 MEASURED DENT FOUND TO BE OUT OF LIMITS AS PER SRM 53-00-01 FIG 101 DETAIL III. CUT OUT DAMAGE AREA FAB DOUBLER TO INCORPORATE EXISTING REPAIR IAW SRM 53-00-01 FIG 101 SHEET 4 DETAIL III. TREATED AND PRIMED DOUBLER REPAIR PARTS AND AREA AS PER SRM 51-20-01. INSTALLED REPAIR AS PER SRM 51-40-02. CATEGORY B REPAIR NEXT INSPECTION F/C CURRENT F/C IS 14420 AS PER SRM 53-00-01 FIG 201 TABLE V.