As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELECTRICAL ODOR AND SMOKE IN AFT CABIN. RT RECIRCULATION FAN INOPERATIVE. PERFORMED SMOKE IN THE CABIN CONDITIONAL INSPECTION IAW AMM TASK 05-51-58-910-801C1, REPLACED POTABLE WATER COMPRESSOR. OPS CHECKED GOOD IAW AMM 38-15-01. REMOVED AND REPLACED RIGHT RECIRCULATION FAN IAW AMM 21-25-01.