What was found
TE FLAP DISAGREE LIGHT CAME BACK ON AFTER SELECTING TE ALT FLAPS LANDED WITH FLAPS 1 EMERGENCY DECLARED. FSEU INSPECTED FOUND FAULT 27-51104, PERFORMED FIM 27-51 TREE 8 10 NO FAULT FOUND SYSTEM OK ON GROUND , FLAPS OPERATIONAL TEST PERFORMED , OK NO FAULT FOUND. PERFORMED FLAP POSITION TRANSMITTER ADJUSTMENT ON TRANSMITTERS 1, 3, 8 PER AMM 27-51-45. R&R FLAP PDU REF AMM 27-51-33.