What was found
STA 807 BLO BETWEEN STR 27L AND STR 27R DENT FOUND OUT OF LIMITS PER SRM 53-00-01 AD5 DENT GOES ACROSS FRAME. REPAIRED REF ECRA 5330-06006 REPAIRED DENT AT STA 807 IAW ECRA 5330-06006.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 807 BLO BETWEEN STR 27L AND STR 27R DENT FOUND OUT OF LIMITS PER SRM 53-00-01 AD5 DENT GOES ACROSS FRAME. REPAIRED REF ECRA 5330-06006 REPAIRED DENT AT STA 807 IAW ECRA 5330-06006.