What was found
ESCAPE PATH INOP FIRST 2 ROWS T/SHOOTING TRACED TO EMERG LIGHTS POWER SUPPLY M1559 CONNECTOR D13208. RECONNECTED D13208 ALL ASSOCIATED EMERGENCY LIGHTS AND EXIT SIGNS WORK OK DURING TEST PER AMM 33-51-00-715-019-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ESCAPE PATH INOP FIRST 2 ROWS T/SHOOTING TRACED TO EMERG LIGHTS POWER SUPPLY M1559 CONNECTOR D13208. RECONNECTED D13208 ALL ASSOCIATED EMERGENCY LIGHTS AND EXIT SIGNS WORK OK DURING TEST PER AMM 33-51-00-715-019-001.