What was found
FWD CARGO BAY STRINGER SPLICE, FRAMES 30 - 31 AT STRINGER 41L CORRODED. REMOVED AND REPLACED THE STRINGER SPLICE IAW SRM 51-42-11, PG 7, TOP COATED AREA IAW SRM 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY STRINGER SPLICE, FRAMES 30 - 31 AT STRINGER 41L CORRODED. REMOVED AND REPLACED THE STRINGER SPLICE IAW SRM 51-42-11, PG 7, TOP COATED AREA IAW SRM 51-75-12.