What was found
DC ESS BUSS SHED AT ROTATION. CIRCUIT BREAKER TRIPPED, LT ELEC BAY. EMERGENCY DECLARED. TROUBLESHOT IAW TSM 24-60-810-810A, IAW AMM 20-16-11, FOUND THE CIRCUIT BREAKER 1PH ON 10 6VU TRIPPED. RESET SAME TESTED ESS BUSS WITH NO FAULTS. OK FOR SERVICE.