As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R2 DOOR SILL FROM FR65 TO FR68 HAS CORROSION. REMOVED CORROSION R2 DOOR SILL AT FR68 FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14 FAB REPAIR ANGLE AND INSTALLED IAW SRM 53-41-14 REV 118. THIS REPAIR IS CONSIDERED PERMANENT WITH NO SRI REQUIRED IAW SRM 53-41-14-300-001 REV 118.