AFT CABIN UNDER FLOOR STRUCTURE, ZONES 171 - 172 HAS CORROSION ON INNER SKIN AT FRAME 66 BETWEEN STRINGERS 42L - 41L. REPLACED THE REINFORCEMENT DOUBLER IAW SRM 51-72-11, REV 118.