What was found
EMERGENCY LIGHT TEST FAILED AT PTP OPS TEST. FOUND THE FWD LT EPSU INTERMITENT LOAD MESSAGES, REPLACED EPSU 10WL IAW AMM 33-51-38 PB401. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHT TEST FAILED AT PTP OPS TEST. FOUND THE FWD LT EPSU INTERMITENT LOAD MESSAGES, REPLACED EPSU 10WL IAW AMM 33-51-38 PB401. OK FOR SERVICE.