What was found
SLAT NR 10, CORRODED ON UPPER SURFACE L/E SKIN AROUND FASTENER. 85 INCHES FROM THE OTBD EDGE, 6 INCHES FROM L/E. REMOVED CORROSION IAW SRM 51-10-02, PAR 15, FIG 1. FOUND TO BE OUT OF LIMITS IAW SRM 57-43-01, FIG 101, DETAIL V. REMOVED DAMAGED AND INSTALLED A FILLER AND DOUBLER IAW SRM 57-43-01, REPAIR 7, PAR 4.