What was found
CORROSION ON THE AFT FLOORBEAM -Y1292 AT FRAME 68, REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53 -00-14-283-002, FIG 10102, SHEET 1. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, PAGE 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON THE AFT FLOORBEAM -Y1292 AT FRAME 68, REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53 -00-14-283-002, FIG 10102, SHEET 1. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, PAGE 1.