What was found
ELEC GENERATOR DRIVE L EICAS ADVISORY LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). EMERGENCY DECLARED. REMOVED AND REPLACED LEFT IDG REF MM 24-11-01, OPS CHECKED IDG REF 24-11-00-700-801, OPS OK
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELEC GENERATOR DRIVE L EICAS ADVISORY LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). EMERGENCY DECLARED. REMOVED AND REPLACED LEFT IDG REF MM 24-11-01, OPS CHECKED IDG REF 24-11-00-700-801, OPS OK