What was found
DOOR 2R SHOWS ARMED ON THE GROUND BUT NOT AT ALTITUDE. ACP'D AMM 52-13-22-820-001-A STEP F, ADJ GIRT BAR FITTINGS TO BRING J6 AND J7 WITHIN LIMITS. OP CHK DOOR AND SLIDE IND PASS REF AMM 52-73-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DOOR 2R SHOWS ARMED ON THE GROUND BUT NOT AT ALTITUDE. ACP'D AMM 52-13-22-820-001-A STEP F, ADJ GIRT BAR FITTINGS TO BRING J6 AND J7 WITHIN LIMITS. OP CHK DOOR AND SLIDE IND PASS REF AMM 52-73-00.