What was found
STAB OUT OF TRIM LIGHT LIGHT ILLUMINATED. EMERGENCY DECLARED. TROUBLESHOT THE STAB TRIM AND FOUND STAB TRIM MOTOR AT FAULT. REMOVED AND REPLACED STAB TRIM MOTOR IAW AMM 27-41-71-400-801. STAB TRIM WORKS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STAB OUT OF TRIM LIGHT LIGHT ILLUMINATED. EMERGENCY DECLARED. TROUBLESHOT THE STAB TRIM AND FOUND STAB TRIM MOTOR AT FAULT. REMOVED AND REPLACED STAB TRIM MOTOR IAW AMM 27-41-71-400-801. STAB TRIM WORKS NORMAL.